Home > The Journal of JAEE > The JAEE Journal Vol. 23 (2023) No.6

The JAEE Journal Vol. 23 (2023) No.6

Technical Papers

A PROPOSAL OF THE SCALING RELATION FOR THE SHORT-PERIOD LEVEL ASSOCIATED WITH THE THREE-STAGE MODEL OF INLAND CRUSTAL EARTHQUAKES
P.6_1-6_18
Masanobu TOHDO, Kensuke ARAI, Jun’ichi MIYAKOSHI, Toshiaki SATO, Hiroyuki FUJIWARA, Nobuyuki MORIKAWA
Released: December 28, 2023

PDF[2.8MB]

abstract

We re-examined the empirical scaling relationship between seismic moment M0 and short-period level A, which is the flat level of the acceleration source spectrum, adopted for setting asperity models of the inland crustal earthquakes in the “Recipe” for predicting strong ground motions published by the Headquarters for Earthquake Research Promotion (2020). Taking into consideration the scaling relationship between seismic moment and rupture area, which is defined as the three-stage model in the Recipe, an empirical equation was newly proposed as a three-fold-line model in which the short-period level was scaled with M01/3, M01/4, and M01/2 for each stage of the three-stage model. By comparing this new empirical equation with the data obtained from earthquake observation records, which included the area and stress drop of the strong motion generation area (SMGA), we found that the three-fold-line model for short-period level could match the short-period level data of SMGAs, and that the stress drop calculated from the empirical equation is independent of the seismic moment, which is consistent with the observational stress drop data of SMGAs.

Technical Report

CHANGE IN DYNAMIC CHARACTERISTICS OF BASE-ISOLATED BUILDINGS WITH IRREGULAR SHAPE BASED ON LONG-TERM VIBRATION RECORDS
P.6_19-6_42
Katsuaki KONNO, Masami TOYODA
Released: December 28, 2023

PDF[9.7MB]

abstract

Long-term structural health monitoring is conducted on the Toyosu campus of Shibaura Institute of Technology. The buildings are installed with accelerometer sensors and incorporated with base isolation devices, which are also installed in the ground. The fast Fourier transform (FFT) was used to analyze the microtremor records for nine years. The result shows a negative correlation between temperature and the natural period of the buildings, and the periods have increased by approximately 5% since the 2011 off the Pacific coast of Tohoku Earthquake. The auto-regressive exogenous (ARX) model was used to analyze the earthquake records. The result shows that the natural period and damping ratio of buildings are dependent on the amplitude of vibration. The periods have increased by 6%–10% due to the abovementioned earthquake, but the damping ratios have not changed.